2025-12-19 01:34:29 mechanical

How to solve the low temperature problem of wall-hung boiler

As an important piece of heating equipment in modern homes, wall-hung boilers have a direct impact on home comfort. Recently, many users have reported that wall-mounted boilers have experienced low-temperature failures, resulting in poor heating effects. This article will combine the hot topics and hot content on the Internet in the past 10 days to provide you with a detailed analysis of the causes and solutions of low-temperature failures of wall-mounted boilers.

1. Common causes of low temperature failures of wall-hung boilers

How to solve the low temperature problem of wall-hung boiler

According to recent user feedback and maintenance data, the main causes of low-temperature failures of wall-hung boilers are as follows:

Cause of failureProportionTypical performance
Water pressure is too low35%The display prompts "E1" or "low voltage"
Insufficient gas supply25%Flame is unstable or fails to ignite
Heat exchanger clogged20%The outlet water temperature is significantly lower than the set value
Temperature sensor failure15%The displayed temperature does not match the actual water temperature
other reasons5%Circuit board failure, water pump abnormality, etc.

2. Solve the low temperature failure of the wall-mounted boiler step by step

Step 1: Check water pressure

The normal water pressure of the wall-mounted boiler should be maintained between 1-1.5Bar. If the pressure is too low:

1. Find the water filling valve at the bottom of the boiler (usually a black knob)

2. Rotate the water injection valve counterclockwise and observe the pressure gauge to 1.5Bar.

3. Close the water filling valve clockwise

Step 2: Confirm gas supply

1. Check whether the gas valve is fully open

2. Confirm that the balance of the gas meter is sufficient (smart meters need to insert a card to check)

3. Observe the flame color: Normally it should be blue, yellow flame indicates insufficient combustion

Step 3: Clean the heat exchanger

Solution to blocked heat exchanger:

Cleaning methodOperational points
chemical cleaningUse special cleaning agent to rinse for 20 minutes
Physical cleaningUse a soft-bristled brush to remove surface carbon

Step 4: Test the temperature sensor

1. Remove the sensor after powering off

2. Use a multimeter to measure the resistance value: it should be about 10kΩ at 25°C.

3. If the value deviation exceeds 20%, it needs to be replaced.

3. Maintenance suggestions to prevent low temperature failures

According to maintenance big data analysis, regular maintenance can reduce the probability of failure by 80%:

maintenance itemscycleOperation content
System blowdownmonthlyOpen the drain valve until the water flows clear
Filter cleaningquarterlyDisassemble the Y-type filter to remove impurities
Comprehensive maintenanceevery yearProfessionals conduct air/water circuit inspection

4. Answers to users’ high-frequency questions

Q: The wall-mounted boiler displays low temperature but the actual water temperature is normal?

A: This is a typical sensor failure. You need to check whether the sensor wiring is oxidized or has poor contact.

Q: What should I do if low temperature faults occur repeatedly?

A: It is recommended to check the following aspects: 1) whether the gas pressure is stable; 2) whether there is air in the system; 3) whether the water pump is operating normally.

Q: How to release low temperature protection in winter?

A: Some models need to press and hold the "+" and "-" keys simultaneously for 5 seconds to enter the engineering mode, and set the code P01 to 0 (for details, please refer to the manual).

5. Professional maintenance suggestions

When encountering the following situations, it is recommended to contact professional after-sales immediately:

1. The fault code continues to display for more than 24 hours

2. Smell obvious gas odor

3. The wall-hung boiler makes abnormal noises

4. The problem still exists after multiple resets

Through the above systematic analysis and solutions, I believe you can effectively deal with low-temperature failures of wall-mounted boilers. Regular maintenance and correct use are key to ensuring efficient operation of your wall-hung boiler.

Next article
  • How to solve the low temperature problem of wall-hung boilerAs an important piece of heating equipment in modern homes, wall-hung boilers have a direct impact on home comfort. Recently, many users have reported that wall-mounted boilers have experienced low-temperature failures, resulting in poor heating effects. This article will combine the hot topics and hot content on the Internet in the past 10 days to provide y
    2025-12-19 mechanical
  • What to do if the floor heat in the house is dry?With the arrival of winter, many families begin to use geothermal heating, but the problem that comes with it is dry indoor air. Dry air not only makes people feel uncomfortable, it can also cause problems such as dry skin and sore throats. This article will combine the hot topics and hot content on the Internet in the past 10 days to provide you with practical methods
    2025-12-16 mechanical
  • What about the Faroli wall-mounted boiler? Hot topics and in-depth analysis across the InternetRecently, as the demand for heating in winter increases, wall-mounted boilers have become the focus of consumer attention. As a well-known European brand, Faroli's wall-mounted boiler products have become significantly more popular in online discussions in the past 10 days. This article will give you a comprehensive analysi
    2025-12-14 mechanical
  • How about the German Bell wall-hung boiler? Popular topics and in-depth analysis of the past 10 days across the InternetRecently, German Bell wall-mounted boilers have become a hot topic in the field of home heating due to their high efficiency, energy saving and intelligence. This article combines the hot discussions on the Internet in the past 10 days to provide you with an in-depth analysis of this product from th
    2025-12-11 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line